APam-2718 is a high molecular weight anionic polyacrylamide (Anionic Polyacrylamide) designed for specialized construction applications, particularly bore piles, drilled shafts, diaphragm walls, and barrettes walls.
With its high molecular weight polymer structure, APam-2718 can be used in polymer-based drilling fluid systems to support borehole stability and improve drilling fluid performance during foundation construction.
1. Product Information
Product Name: APam-2718
Chemical Type: Anionic Polyacrylamide
Polymer Type: Anionic Polymer
Molecular Weight: High Molecular Weight
Main Application: Drilling Fluid / Foundation Construction
Applications: Bore Piles, Diaphragm Walls, Barrettes Walls, Drilled Shafts
Packaging: 25 kg/bag
Brand: Unicon Global
APam-2718 is a specialty chemical developed for drilled shaft construction, providing a practical polymer solution for foundation and underground construction projects.

2. Applications & Benefits
Bore Pile and Drilled Shaft Construction
APam-2718 can be incorporated into polymer drilling fluid systems used for bore piles and drilled shafts. It helps support the stability of the borehole during drilling operations.
Borehole Wall Stabilization
The high molecular weight anionic polymer can interact with fine particles in the drilling system, helping improve the overall performance of the drilling fluid and supporting borehole stability under suitable operating conditions.
Drilling Fluid Performance
APam-2718 can help control the properties of polymer-based drilling fluids and contribute to better management of fine particles during the drilling process.
Diaphragm & Barrettes Walls
The product is suitable for applications involving:
- Bore Piles
- Drilled Shafts
- Diaphragm Walls
- Barrettes Walls
- Foundation and underground construction
Its application should be adjusted according to the geological conditions, drilling method, water quality, and technical requirements of each project.
3. Application & Dosage Guidelines
APam-2718 should be used according to the technical requirements of the project and actual geological conditions. There is no single dosage suitable for every construction site.
Recommended Application Procedure
Step 1: Prepare the Water
Use suitable water according to the project’s technical requirements. Water quality should be checked before polymer preparation.
Step 2: Add APam-2718
Slowly add APam-2718 into the water while maintaining suitable agitation. Avoid adding a large quantity at once, as this may cause lump formation.
Step 3: Hydration and Mixing
Continue mixing under appropriate conditions until the polymer is properly hydrated and evenly dispersed throughout the solution.
Step 4: Test the Drilling Fluid
Before use, check the relevant drilling fluid properties according to the project’s requirements, including viscosity, fluid behavior, borehole stability, and other applicable parameters.
Step 5: Adjust the Dosage
The optimum dosage should be determined through laboratory testing, jar testing, or field trials based on soil conditions and the specific drilling system.
Important: The dosage should not be determined solely by a general recommended rate. Testing under actual project conditions is recommended to achieve optimum performance.
4. Storage
Proper storage is important to maintain the quality and performance of APam-2718.
- Store in a cool, dry and well-ventilated area.
- Keep the product away from direct contact with water and excessive moisture.
- Keep the original packaging sealed until use.
- Protect the product from direct sunlight and high temperatures.
- Do not place bags directly on wet or damp floors.
- Handle bags carefully to prevent tearing or package damage.
- After opening, properly reseal any unused product to minimize moisture absorption.
- Follow the applicable SDS and TDS recommendations for handling and storage.
Appropriate personal protective equipment, such as gloves, protective clothing and respiratory protection where required, should be used during handling.
5. Buy APam-2718 from Unicon Global
Unicon Global supplies APam-2718 High Molecular Weight Anionic Polyacrylamide for specialized construction and foundation applications, including bore piles, drilled shafts, diaphragm walls, and barrettes walls.
The product is available in 25 kg bags, providing a convenient packaging format for transportation, storage, and construction-site operations.
Why Choose APam-2718 from Unicon Global?
- High molecular weight anionic polyacrylamide for specialized applications.
- Suitable for polymer drilling fluid systems.
- Applicable to bore piles, drilled shafts, diaphragm walls and barrettes walls.
- Convenient 25 kg/bag packaging.
- Suitable for contractors, foundation specialists, construction companies and chemical distributors.
- Technical consultation and product support available according to project requirements.
Contact Unicon Global today for APam-2718 product information, technical consultation and quotation based on your project requirements.
Unicon Global Contact Information
UNICON GLOBAL
Office-C1, Building-1F-F8859, Ajman Free Zone, PO Box No. 4441, U.A.E.
Email: unicon.global604@gmail.com
Website: unicon-global.net
Tel: +971 503 92 36 39 / +971 5068 03578

Reviews
There are no reviews yet.